The Libraries will be performing routine maintenance on UWSpace on October 13th, 2025, from 8 - 9 am ET. UWSpace will be unavailable during this time. Service should resume by 9 am ET.
 

Critical evaluation of aptamer binding for biosensor designs

dc.contributor.authorZhao, Yichen
dc.contributor.authorYavari, Kayvan
dc.contributor.authorLiu, Juewen
dc.date.accessioned2025-09-22T15:23:21Z
dc.date.available2025-09-22T15:23:21Z
dc.date.issued2021-11-13
dc.descriptionThe final publication is available at Elsevier via https://doi.org/10.1016/j.trac.2021.116480. © 2021. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.description.abstractOver the last three decades, numerous aptamer-based biosensors have been reported. The basis of these sensors is the selective binding of target analytes by aptamers. In the last few years, a number of papers have been published questioning the binding ability of some popular aptamers such as those documented for As(III), ampicillin, chloramphenicol, isocarbophos, phorate and dopamine. In this article, these papers are reviewed, and the binding assays are described, which may provide possible reasons for obtaining false positive aptamers. Additionally, relevant aptamer selection methods and typical characterization steps are described. It is found that for small molecular targets, using an immobilized library might result in better aptamers. Furthermore, the importance of carefully designed controls to ensure the quality of binding assays is discussed, especially in the case of mutated nonbinding aptamers. Only then, with fully validated aptamers, can subsequent biosensor design bring about meaningful results.
dc.identifier.urihttps://doi.org/10.1016/j.trac.2021.116480
dc.identifier.uri10.1016/j.trac.2021.116480
dc.identifier.urihttps://hdl.handle.net/10012/22506
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofseriesTrends in Analytical Chemistry; 146; 116480
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationalen
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.titleCritical evaluation of aptamer binding for biosensor designs
dc.typeArticle
dcterms.bibliographicCitationZhao, Y., Yavari, K., & Liu, J. (2022). Critical evaluation of aptamer binding for biosensor designs. TrAC Trends in Analytical Chemistry, 146, 116480. https://doi.org/10.1016/j.trac.2021.116480
uws.contributor.affiliation1Faculty of Science
uws.contributor.affiliation2Chemistry
uws.peerReviewStatusReviewed
uws.scholarLevelFaculty
uws.typeOfResourceTexten

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
false aptamers-4-revised2.pdf
Size:
2.09 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.47 KB
Format:
Item-specific license agreed upon to submission
Description: