dc.description(© 2014 IEEE) Nasr-Azadani, E., Canizares, C. A., Olivares, D. E., & Bhattacharya, K. (2014). Stability Analysis of unbalanced distribution systems with synchronous machine and DFIG based distributed generators. IEEE Transactions on Smart Grid, 5(5), 2326–2338. https://doi.org/10.1109/tsg.2014.2321709
dc.description.abstractThere are many technical aspects and challenges in distributed generation (DG) that have not been properly understood and addressed so far. Distribution systems cannot be considered as balanced three-phase systems, because these are inherently unbalanced in steady-state operation. A full characterization of the unbalanced system with respect to system stability allows a better understanding of the dynamic behavior of such systems. This paper presents a comprehensive investigation of the effects of system unbalance on the stability of the distribution systems with synchronous generator (SG) and doubly-fed induction generator (DFIG) based DG units at different loading levels. Detailed steady-state and dynamic analyses of the system are performed. Based on classical voltage, small-perturbation and transient stability studies, it is demonstrated that system unbalance can significantly affect the distribution system dynamic performance, in ways that have not been discussed in the technical literature so far. A simple and effective control strategy based on an Unbalanced Voltage Stabilizer (UVS) is also proposed to improve the system control and the stability of unbalanced distribution systems with SG and DFIG. Eigenvalue analyses and time-domain simulations (TDS) demonstrate the effectiveness of the proposed UVS for unbalance conditions.
dc.identifier.doi10.1109/tsg.2014.2321709
dc.identifier.issn1949-3053
dc.identifier.issn1949-3061
dc.identifier.urihttps://doi.org/10.1109/TSG.2014.2321709
dc.identifier.urihttps://hdl.handle.net/10012/22077
dc.language.isoen
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)
dc.relation.ispartofIEEE Transactions on Smart Grid
dc.relation.ispartofseriesIEEE Transactions on Smart Grid; 5(5)
dc.subjectstability studies
dc.subjectunbalanced power systems
dc.subjectdistributed generation
dc.subjectdoubly-fed induction generator
dc.subjectvoltage control
dc.titleStability Analysis of Unbalanced Distribution Systems With Synchronous Machine and DFIG Based Distributed Generators
dc.typeArticle
dcterms.bibliographicCitationNasr-Azadani, E., Canizares, C. A., Olivares, D. E., & Bhattacharya, K. (2014). Stability Analysis of unbalanced distribution systems with synchronous machine and DFIG based distributed generators. IEEE Transactions on Smart Grid, 5(5), 2326–2338. https://doi.org/10.1109/tsg.2014.2321709
oaire.citation.issue5
oaire.citation.volume5
uws.contributor.affiliation1Faculty of Engineering
uws.contributor.affiliation2Electrical and Computer Engineering
uws.peerReviewStatusReviewed
uws.scholarLevelFaculty
uws.typeOfResourceTexten

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Stability Analysis of Unbalanced Distribution_AAM.pdf
Size:
549.55 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.47 KB
Format:
Item-specific license agreed upon to submission
Description: